44 installation, Mantel requirements, For qualified installers only) – Avalon Firestyles 564 Diamond-Fyre GSR2 Installation User Manual

Page 44: Combustible mantels, Non-combustible mantels

Advertising
background image

44 Installation

(for qualified installers only)

© Travis Industries

4140926

100-01395

Mantel Requirements

Combustible Mantels

 Use the table below to determine the maximum mantel depth allowed. The mantel depth (measured

from the face of the fireplace) must fall in the shaded portion of the table.

 Any material that protrudes more than 3/4” (19mm) from the non-combustible facing is considered a

mantel and must meet the mantel requirements.

Examples:

- If you wish to have a 6” (152mm) deep mantel, it must be at least 37” (940mm) above the base of the fireplace.
- If you wish to have a 2” (51mm) deep breastplate, it must be at least 36” (914mm) above the base of the fireplace.

Non-Combustible Mantels

Non-combustible mantels must meet the clearances listed for combustible mantels. However, if you do
wish to reduce the clearances by using a non-combustible mantel, the following requirements must be met:

 Non-combustible

mantel

and facing must extend
from the top of the
appliance to the top
surface of the mantel.

 A

non-combustible

header must be used
(metal stud).

Combustible Mantel

Combustible mantel columns (legs) that protrude more than 3/4" (0.75mm) from the glass frame must
meet the 1" (25mm) sidewall clearance. If they protrude 3/4" (0.75mm) or less, they may be placed
directly to the side (but not in front) of the fireplace.

Non-combustible mantel columns do not have a minimum clearance.

a

b

30-1/4"
768mm

Mantel Height

Above Base of

Fireplace (a)

39"+(991mm+)

36"(914mm)

35"(889mm)

34"(864mm)

33"(838mm)

37"(940mm)

38"(965mm)

32"(813mm)

31"(787mm)

30"(762mm)

Top of Fireplace

(not stand-off)

NOTE: No combustibles may be
installed in front of fireplace.

0" 1" (25mm)

2" (51mm)

8" (203mm)

7" (178mm)

6" (152mm)

5" (127mm)

4" (102mm)

3" (76mm)

9" (229mm)

10" (254mm)

11" (279mm)

12" (305mm)

Maximum Mantel Depth (b)

SIDE OF FIREPLACE

Drywall

Non-Combustible Mantel

Non-Combustible Framing (metal studs)

must be used for the header.

Non-Combustible Facing

Advertising