Caution, 2 introduction, Overview – Avalon Firestyles 564 Diamond-Fyre GSR2 Installation User Manual

Page 2: Listing details, Massachusetts approval, National fireplace institute

Advertising
background image

2 Introduction

© Travis Industries

4140926

100-01395

Overview

This manual details the installation requirements for
the 564 DF GSR2 fireplace. For operating and
maintenance instructions, refer to the 564 DF
Owner's Manual (part # 100-01396).

Listing Details

The listing label is attached to the appliance near
the gas control valve. A copy is shown to the right.

Massachusetts Approval

This manual has been submitted to the
Massachusetts Board of State Examiners of
Plumbers and Gas Fitters

National Fireplace Institute


Report No. 100884869PRT

-001

Control No. 4000515

V

e

nted Gas Fireplace Heater

564 DF GSR2

Tested to:

ANSI Z21.88-2014/CSA

2.33-2014 “V

ented Gas Fireplace Heater”, CGA

2.17-M91 (R2009) “Gas Burning

Heating

Appliances for Manufactured Homes”, and CSA

P

.4.1-09 T

esting method for measuring annual fireplace

efficiency

.

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,

ANSI Z223.1/NFP

A 54, or Natural Gas and Propane Installation Codes, CSA

B149.1.

This appliance must be installed in accordance with the current Standard CAN/CSA

Z240 MH, Mobile Housing,

in Canada or with the Manufactured Home Constructions and Safety Standard, T

itle 24 CFR, Part 3280, in the

United States, or when such a standard is not applicable,

ANSI/NCSBCS

A225.1/NFP

A 501A, Manufactured Home

Installation Standard.

This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the optional factory conversion kit must be used. Part No. 94400999 register kit may be used.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA

only) or mobile home, where not prohibited by local

codes. See owner

’s

manual for details. This appliance is not convertible for use with other gases, unless a

certified kit is used.

This vented gas fireplace heater is not for use with air filters.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

This appliance must be properly connected to a venting system in accordance with the manufacturer

’s

installation instructions. Use only approved coaxial direct vent system to vent this appliance to the exterior

. See

owner

’s

manual for approved brands of venting.

If the vent-air intake system is disconnected for servicing or any other reason, it must be resealed and / or reinstalled.

W

ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property

damage. Refer to the owner

’s

information manual provided with this appliance. For assistance or additional

information consult a qualified installer

, service agency or the gas supplier

.

VENTED GAS FIREPLACE HEA

T

ER - NOT FOR USE WITH SOLID FUEL

Minimum Clearances to Combustibles

Fireplace to

Adjacent W

all

W

ood Floor Beneath Fireplace

Back to Enclosure

1” (26 mm) 0” (0 mm)

0.5” (13 mm)

To

p to Enclosure (from stand-offs)

Sides to Enclosure Base of Fireplace to a Mantel

0” (0 mm)

0.5” (13 mm)

See Owner

’s

Manual

FAN TYPE VENTED CIRCULA

TOR

Blower Electrical Rating: 1

15V

., 1.5

Amps, 60 Hz

Part No. 99000162 fan or blower assembly may be used.

DANGER! Risk of Electric Shock. Disconnect power before servicing unit.

Minimum Inlet Pressure (inches W

.C.)

Maximum Inlet Pressure (inches W

.C.)

Manifold Pressure on “HI” (inches W

.C.)

L.P

.

11

13”

10”

N.G. 5.5”

7”

3.8”

Input Rate on “HI” (BTU/Hr)

Input Rate on “LO” (BTU/Hr)

Orifice Size (DMS)

L.P

.

20,500

10,780

1.3mm

N.G. 20,500 11

,310

#46

This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4,500 feet (0-1370m).

For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.

See owner

’s

manual for information on making these changes.

2015

2016

2014

Feb.

Mar

.

Jan.

May

Jun.

Apr

.

Aug.

Sep.

Jul.

Nov

.

Dec.

Oct.

MANUF

ACTURE DA

TE:

W

ARNING: Failure to install this appliance per the manufacturer

’s

instructions or failure to use only parts

specifically approved with this appliance may result in property damage or personal injury

.

12521 Harbour Reach Drive

Mukilteo, W

A

98275

Manufactured by:

www

.travisproducts.com

CAUTION:

Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.

0910

Advertising