32 installation, Rear vent configuration with vertical termination, For qualified installers only) – Avalon Firestyles 564 Diamond-Fyre GSR2 Installation User Manual

Page 32

Advertising
background image

32 Installation

(for qualified installers only)

© Travis Industries

4140926

100-01395

Rear Vent Configuration with Vertical Termination

 The termination must fall

within the shaded area shown
in the chart. Use the
indicated restrictor and
diffuser positions.

 Up to four elbows (45° or 90°)

may be used.

 Only one horizontal elbow

may be used.

5 feet (1.5m)

0 feet

0 feet

5 feet (1.5m)

0 feet

20 feet (6m)

20 feet (6m)

5 feet (1.5m)

10 feet (3m)

5 feet (1.5m)

10 feet (3m)

0 feet

15 feet (4.5m)

20' max (6m)

10 feet (3m)

15 feet (4.5m)

15 feet (4.5m)

20' max (6m)

10 feet (3m)

15 feet (4.5m)

40' max (12m)

Exhaust Restrictor # 5

Intake Restrictor # 2

Diffuser Position # 2

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

40' max (12m)

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

Exhaust Restrictor # 4

Intake Restrictor # 2

Diffuser Position # 2

Exhaust Restrictor # 2

Intake Restrictor # 2

Diffuser Position # 2

This is considered a horizontal

elbow (it does not matter

whether it turns right or left).

It may be a 90° or 45° elbow.

This is considered a

vertical elbow

Horizontal length is calculated by adding

both lengths of horizontal run

(Horizontal Length = H1 + H2).

H1

H2

Advertising