User manual – Bolide SVR9000s MO User Manual

Page 10

Advertising
background image

User Manual

7

2.3.4 Alarm I/O

The device connected to eight groups of alarm input and two groups of alarm output. When brake plate is stepped

on illustrated in below Picture, mobile DVR can detect high level.

Alarm output belongs to level output and driving capacity is 200 MA.

If driving power is too strong, the relay is required. Please refer to the below connection configuration.

2.3.5 Speed sensor

1. Connect speed sensor input of Camera to pulse output of car sensor

2. If speed meter have pulse signal output, the speed sensor input of camera can directly connected to the ouput port

of speed meter.

If speed meter has no pulse signal output, that means you need to connect pulse signal output of speed sensor to the

speed meter input.

3. Camera will receive pulse signal from speed sensor through Menu setting.

4. How to calculate pulse count per kilometer. Generally the wheel turn a circle, sensor speed will generate eight or

sixteen pulses.

However, it is difficult to calculate the pulse counts by hand in the practical application. We calculate the value

by driving one kilometer.