ARC GOUGING MODULAR DRIVE TROUBLESHOOTING GUIDE, (CONT’D.)

The Modular Drive System is equipped with internal fault diagnostic LEDs and test Points

10 Speed troubleshooting as shown below. Test point evaluation should be performed by

a qualified technician using a volt meter. If a qualified technician is not available, return the

unit to the factory for repair. Always unplug the power cord before opening the case.

Figure 1. Troubleshooting Test Points

TEST POINTS

TP1 -15V

TP2 GND

TP3 +15V

TP4 Tractor + Speed Command

TP5 Tractor - Speed Command

TP6 Weaver + Speed Command

TP7 Weaver - Speed Command

TP8 Height + Speed Command

TP9 Height - Speed Command

L1 -15v

L2 +15V

L3 Height Off

L4 Weaver Off

L5 Tractor Off

INTERCONNECT

CARD

POWER SUPPLY

OUTPUT CONNECTOR

POWER

ENTRY

MODULE

RFI FILTER OUTPUT

POWER

SUPPLY

SPEED CARD

INPUT POWER

CONNECTOR

TP9

TP4

TP5

L2

L1

TP1

TP6

TP3

TP2

L3

L4

L5

RFI FILTER

SPEED

CARD

TP8