1-2

Introduction

Séance Interface 7975

Revision SE2005-2

418

&RQQHFWLRQV#0#%1&

Figures 1-1, 1-2, and 1-3 on page 1-4 show how to connect the Séance box to the
console and the computers running SAM.

41814

(WKHUQHW#0#%1&

The Séance box communicates with the PCs over a 10Base-2 Ethernet connection
via a 50 ohm BNC cable terminated at each end with a 50 ohm terminator. The
Séance box has two BNC connectors for each PC interface, which are wired in paral-
lel inside. A 50 ohm terminator plugs into the BNC socket labelled TERMINATOR
and the Ethernet cable plugs into the BNC socket labelled COMPUTER. A termina-
tor and T-piece are used to connect the Ethernet cable to the PC.

FIG 1-1. Séance rear panel connections for BNC