CDI-46 Installation and Setup Guide V1.0

23

46-120 Serial Control

The CDI-46 is equipped with a bi-directional RS-232 serial interface.
As a receiver, the interface permits external control of almost every 46-120 function, parameter and setting. The CDI-46
appears as a DCE (Data Communications Equipment) device to controlling equipment. As the controlling device will probably
be configured as a DTE device, this requires the use of a straight (uncrossed) cable with the Tx (Data Transmit) pins at the cable
ends connected to each other and the Rx pins (Data Receive) similarly connected to each other.

Pinout

The rear panel

RS232 connector is a 3-pin, 3.5 mm-pitch screw-terminal connector. The pinout is shown in the table:

PIN

LABEL

FUNCTION

1

Gd

Ground

2

Rx

Data transmit

3

Tx

Data receive

Note that not all control systems interpret “Tx” and “Rx” the same way, and the installer should check whether pins 2 and 3

should be “crossed” within the cable.

Port parameters:

PARAMETER

VALUE/SETTING

Data Type

RS-232 serial

Data Speed

4800/9600/19200/38400/57600/115200 baud, software-selectable

Word Length

8 bits

Parity

None

Stop Bits

One

The CDI-46 is additionally able to receive the same serial commands in the form of TCP/IP data via the

ETHERNET INTERFACE connector.
The full RS-232 protocol is beyond the scope of this manual, but is available to view in your browser (see “Documents” on