Figure 2-13 TOS Switch Rules dialog

Click on the Add button to add a new ToS rule, using the dialog shown in

figure 2-14.

• Name – Enter a user-defined text label for circuit identification.
• Identifier – Enter an integer value in the range of 1 to 63. Entering a value

of 0 will result in no switch.

• Switch Type – Enter an integer value in the range of 64 to 254 at the

prompt to inform the VMS what switching policy to use. Entering a value

of 0 will result in no switch.

• Switch Rate – Enter the desired data rate for this service type. Valid

entries are from 0 to 155000000 bps. This setting will override the VMS

set policy value.

• Timeout – This timer monitors the defined packet flow. Once data stops

for the duration of the timer setting, the link state will be restored to the

Home State condition for this Remote. Valid entries are from 1 to 60

seconds.

After field entry, clicking the Add button will update the ToS Switch Rules

table with the new configuration. Note that the Add Type of Service Rule dialog

remains open after adding a rule so that additional rules can be added easily.

Click the Close button to return to the ToS dialog.