W415-0895 / C / 03.13.12

30.1A

Installation and servicing to be done by a qualifi ed installer.
A.

Move the appliance into position and secure.

B.

If equipped with a fl ex connector the appliance is designed to accept a 1/2” gas supply. Without the

connector it is designed to accept a 3/8” gas supply. The appliance is equipped with a manual shut off

valve to turn off the gas supply to the appliance.

C.

Connect the gas supply in accordance to local codes. In the absence of local codes, install to the

current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI

Z223.1 / NFPA 54 in the United States.

D.

When

fl exing any gas line, support the gas valve so that the lines are not bent or kinked.

E.

The gas line fl ex-connector should be installed to provide suffi cient movement for shifting the burner

assembly on it’s side to aid with servicing components.

F.

Check for gas leaks by brushing on a soap and water solution. Do not use open fl ame.

!

WARNING

RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS

SPARKS OR OPEN FLAMES.

SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT

WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE

PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT

THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND

ELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.

ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.

HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS

LINE AT TEST PRESSURES ABOVE 1/2 PSIG.

VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.

4.8 GAS

INSTALLATION

2”

12.000”

NOTE: Connect the gas supply to the 1/2” shut off and fl ex connector (supplied). Ensure gas supply
is secured and that there is suffi cient movement of the connector to permit lifting the burner base
assembly for component servicing.