Warning – Continental Fireplaces CLHD45 User Manual

Page 6

Advertising
background image

6

W415-0895 / C / 03.13.12

4.1A

THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER

to

conform with local codes. Installation practices vary from region to region and it is important to know the

specifi cs that apply to your area, for example in Massachusetts State:

This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth

of Massachusetts.

The appliance damper must be removed or welded in the open position prior to installation of a appliance

insert or gas log.

The appliance off valve must be a “T” handle gas cock.

• The

fl exible connector must not be longer than 36 inches.

A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent

sealed combustion product.

The installation must conform with local codes or, in

absence of local codes, the National Gas and Propane

Installation Code CSA B149.1 in Canada, or the National

Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United

States. Suitable for mobile home installation if installed in

accordance with the current standard CAN/CSA Z240MH

Series, for gas equipped mobile homes, in Canada or

ANSI Z223.1 and NFPA 54 in the United States.

As long as the required clearance to combustibles is

maintained, the most desirable and benefi cial location

for an appliance is in the center of a building, thereby

allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the

room where the appliance is to be located should be considered. If possible, you should choose a location

where the vent will pass through the house without cutting a fl oor or roof joist.

If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood

fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.

Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must

be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.

We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute

® (NFI) as NFI Gas

Specialists

www.nficertified.org

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,

WITH THE GLASS DOOR OPENED OR REMOVED.

PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.

PROVIDE ADEQUATE VENTILATION.

NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.

OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” FROM THE

FRONT FACE OF THE APPLIANCE.

SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT

WHEN THE APPLIANCE IS OPERATING.

FIRE RISK. EXPLOSION HAZARD.

HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS

LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE

TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG.

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.

USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING

COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.

!

WARNING

2.2 GENERAL

INSTRUCTIONS

Advertising