Warning – Continental Fireplaces CLHD45 User Manual

Page 34

Advertising
background image

34

W415-0895 / C / 03.13.12

6.4 GLASS

EMBERS

NOTE: Care must be taken to ensure glass embers are kept .250” clear of the pilot area on the media
tray and aren’t interfering with the pilot operation.
Glass embers must not cover burner ports.
When the fl ames impinge on the glass, the glass may discolour slightly and the edges may soften.

74.2A

Evenly spread the glass media onto the media tray, ensuring no glass media falls onto the burner. If this hap-
pens, insert a clean bag into your vacuum cleaner and vacuum out the glass media. Replacement glass can
be purchased from your local authorized dealer / distributor.

CLEANING GLASS MEDIA
Glass media may have a fi ne oil residue that needs to be cleaned prior to installation. Clean the glass with mild
dish soap, drain, rinse thoroughly and dry before placing around the burner.

CLEAN THE GLASS MEDIA PRIOR TO INSTALLATION. BEFORE APPLYING THE CLEANED GLASS, ENSURE

THAT IT IS DRY.

DO NOT CHANGE OR SUBSTITUTE THE GLASS MEDIA MATERIAL PROVIDED WITH THIS APPLIANCE. IF

REPLACING, USE ONLY THE REPLACEMENT GLASS MEDIA AVAILABLE FROM YOUR AUTHORIZED

DEALER / DISTRIBUTOR.

!

WARNING

PILOT

AREA

BURNER

PORTS

Advertising