Continental Fireplaces CLHD45 User Manual
Page 46
46
W415-0895 / C / 03.13.12
A.
Carefully lift the valve train assembly and turn off
the manual shut-off valve, see “VALVE TRAIN
ASSEMBLY” and “GAS INSTALLATION” section.
NOTE: A new gasket may be required, when
re-installing the
valve train assembly, contact
your local Authorized dealer / distributor.
Disconnect the fl ex connector from the valve.
Remove the valve wire connections, labeling
each one to aid with re-connection.
B.
Remove the four screws from the valve bracket
and remove the valve.
C.
Replace all components before returning the
appliance to service.
D.
Check for gas leaks by brushing on a soap and
water solution.
VALVE
VALVE
BRACKET
GASKET
11.3 CARE OF PLATED PARTS
6.1
If the appliance is equipped with plated parts, you must clean fi ngerprints or other marks from the plated
surfaces before operating the appliance for the fi rst time. Use a glass cleaner or vinegar and towel to clean.
If not cleaned properly before operating for the fi rst time, the marks can cause permanent blemishes on
the plating. After the plating is cured, the fi ngerprints and oils will not affect the fi nish and little maintenance
is required, just wipe clean as needed. Prolonged high temperature burning with the door ajar may cause
discolouration on plated parts.
NOTE: The protective wrap on plated parts is best removed when the assembly is at room
temperature but this can be improved if the assembly is warmed, using a hair dryer or similar heat
source.
11.4 VALVE REMOVAL
11.5 RESTRICTING VERTICAL VENTS
77.2
Vertical terminations may display a very active fl ame. If this appearance is not desirable, the vent exit may be
restricted using restrictor supplied. This reduces the velocity of the exhaust gases, slowing down the fl ame
pattern and creating a more traditional appearance.
A.
Line up the holes on the restrictor plate with the holes in the top of the fi rebox and secure.
OPTIONAL
RESTRICT
OR PLA
TE