5.2.15 CLEAR

Syntax: clear

The clear or clr command is only visible when the unit is logged in. The command has no
additional arguments. It sets all the measurement and error counters to zero.

5.2.16 MODULE DISPLAY MEASUREMENTS

Syntax: dm

The dm command displays the current measurements of the unit and is only visible when the
user is logged in. The command has no arguments.

This measurement command is different from the module measurement command available
through the Node console or StarKeeper. The following distinguishes between the two types of
Universal Trunk measurements.

The measurement report for the node level DMEAS command reports measurement counters for
From Bus Packets, To Bus Packets and Percent Utilization.

The measurement report for the module level (dm) command reports measurement counters for
Packet, Frame, Error and Ethernet Counters plus specific per protocol counters.

The table below itemizes the measurements available using the dm command. The base
measurements are always displayed, and the error and exception counters are only displayed if
nonzero.

Interface

Type

Protocol

Description

10, 10/100, Fiber

Base

All

Number of 10BaseT Packets Received

10, 10/100, Fiber

Base

All

Number of 10BaseT Packets Transmitted.

10, 10/100, Fiber

Except

All

Number of ICMP Echo Requests Received.

V.35, RS232, DSU

Except

HDLC, FR

Number of Serial Trunk Frames Received.

RS232, V.35, DSU

Except

HDLC, FR

Number of Serial Trunk Frames Transmitted.

DSU

Except

ATM

Number of ATM AAL5 Trunk Frames Received.

DSU

Except

ATM

Number of ATM AAL5 Trunk Frames Transmitted.

10, 10/100, Fiber

Error

All

Number of Ethernet Discards (Resource).

10, 10/100, Fiber

Error

All

Number of Late Collisions ( TX).

10, 10/100, Fiber

Error

All

Number of Under-run. ( TX).

10, 10/100, Fiber

Error

All

Number of packets which exceeded the Retry Limit ( TX ).

10, 10/100, Fiber

Error

All

Number of Carrier Sense Lost ( TX ).

10, 10/100, Fiber

Error

All

Number of Frame Collisions (RX).

10, 10/100, Fiber

Error

All

Number of Receiver Overruns (RX).

10, 10/100, Fiber

Error

All

Number of Receive CRC Errors. (RX).

10, 10/100, Fiber

Error

All

Number of Short Frame Errors. (RX).