2 [f16] no-signal input monitoring time, F16] no-signal input monitoring time, No-signal input monitoring time – IDK OPF-H1000D User Manual

Page 29

Advertising
background image

OPF-TH1000D/OPF-RH1000D User’s Guide

29

7.2.2 [F16] No-signal input monitoring time

You can set the monitoring time for when the source device does not output video signals due to the changes

of transmitter EDID or turning on/off the transmitter or source device.

Changing EDID

ON

OFF

The OPF requests the source
device to output video signals

Monitoring time

Hot plug

ON

OFF

Video signals from

source device

Monitoring time

Setting value

oFF: OFF

02 to 15: 2 to 15 seconds [Default: 10]

Notes:
● If you use the power-saving function or dual monitor of the PC (source device), set this menu to “OFF”.

PCs may release or cancel those functions if they receive the request to output video signals.

● If the set time is shorter than the timing that the source device outputs video, the source device may not

output video signals because it sets the output signals repeatedly. In these cases, set the monitoring time

longer.

Changing EDID

Monitoring

time

ON

OFF

Monitoring

time

Monitoring

time

Video output timing of source device

Video signals

from source

device

FDX requests source device to output

video signals

Advertising