2 setting command, Gpm / @spm, Acquiring version information – IDK OPF-H1000D User Manual

Page 42: Setting command, Hot plug mask off setting (only receiver)

Advertising
background image

OPF-TH1000D/OPF-RH1000D User’s Guide

42

8.3.2 Setting command

@GPM / @SPM

Setting time for ignoring video output request signals: Hot Plug mask off setting

(only receiver)

Function

Acquisition

Setting

Format

@GPM

@SPM, time

Return value

format

@GPM, time

@SPM, time

Parameter

time: If the request signals are repeated in a short cycle, video may not be output. This

problem can be solved by setting the ignoring time.

0 = OFF [Default]

2 to 15 = 2 to 15 seconds

Example

@GPM

@GPM,0

Acquires the current setting status.

The setting is OFF.

@SPM,2

@SPM,2

Sets the ignoring time to 2 seconds.

The setting has been changed to 2 seconds.

Related info.

@GIV

Acquiring version information

Function

Acquisition

Format

@GIV

Return value

format

@GIV, id, ver

Parameter

id: model name

ver: firmware version

Example

@GIV

@GIV,OPF-RH1000D ,1.00

Acquires the version information of the firmware.

The firmware version of the OPF-RH1000D is

ver.1.00. (for transmitter, the firmware version of

the “OPF-TH1000D” will be returned.)

Related info.

7.2.13 [F90] Version

Advertising