Al_setinputconfigglobal – Measurement Computing ADLIB WIN User Manual

Page 109

Advertising
background image

Chapter 31 Input Configurations

24-5

24.3 AL_SetInputConfigGlobal

Prototype

C\C++

ERRNUM

AL_SetInputConfigGlobal(LHLD

lhld, lpstr lpstrInputConfig);


Visual Basic for Windows

Function

AL_SetInputConfigGlobal(ByVal

lhld As Long, ByVal lpstrInputConfig As

String) As Long

LHLD lhld

handle of the LDSD

lpstr lpstrInputConfig

address of the InputConfig type string


The AL_SetInputConfigGlobal function globally sets all InputConfig list input types to the specified
lpstrInputConfig in the LDSD.

Parameter Description

lhld

Identifies the instance of the logical device subsystem to be released.


LpstrInputConfig

Points to the desired InputConfig type setting string. The available string
settings are device independent and are verified by ADLIB against the available
InputConfig options specified in the device's capabilities file.


Returns:
On success ERRNUM is set to 1, otherwise ERRNUM contains the last error code that occurred during the
call.

Related Functions:
AL_SetInputConfigList
AL_GetInputConfigList

Supported Logical Device Subsystems:
Pci55xx Series: ADC0, Options:

“DI“,“SE“,“PD“