Chapter 18 Analog Output

17-1

17. ANALOG OUTPUT

The Analog Output function immediately sets the specified DtoA channel to specified voltage. This is
typically used for slower software transfer modes requiring level oriented voltage output application
requirements. For higher speed applications the DMA transfer mode allows timed waveform generation.
To use the AL_SetDAOutput function with the Pci55xx DAC0 or DAC1 the clocking source must also be
configured for “SOFTWARE_CONVERT”, in addition DAC0’s Trigger and Gating modes must be
DISABLED.

17.1 AL_SetDaOutput

Prototype

C\C++

ERRNUM

AL_SetDaOutput(LHLD

lhld, double dData, long lUnits);


Visual for Basic Windows

Function AL_SetDaOutput(ByVal lhld As Long, ByVal dData As Double,

ByVal lUnits As Long) As Long

LHLD lhld

handle of the LDSD

double dData output

data

long lUnits

specifies the output data units


The AL_SetDaOutput function immediately sets a hardware analog output port to the dData value.

Parameter Description

lhld

Identifies the instance of the logical device subsystem.


dData

Specifies the data output value.


lUnits

Sets the units in which the above dData output parameter is specified. The

available settings are defined as AL_VOLTS or AL_RAWDATA in the ADLIB

include

file.


Returns:
On success ERRNUM is set to 1, otherwise ERRNUM contains the last error code that occurred during the
call.

Related Functions:
NONE

Program References:
Adlda01

Supported Logical Device Subsystems:
Pci55xx Series: DAC0, DAC1