PCI-DAS6013 and PCI-DAS6014 User's Guide

Specifications

37

Configurable AUXIN<5:0>, AUXOUT<2:0> external trigger/clocks

The PCI-DAS6013 and PCI-DAS6014 provide nine user-configurable trigger/clock pins available at the
100-pin I/O connector. Of these, six are configurable as inputs while three are configurable as outputs.

AUXIN<5:0> sources (software
selectable)

A/D CONVERT:

External ADC convert strobe

A/D TIMEBASE IN:

External ADC pacer timebase

A/D START TRIGGER:

ADC Start Trigger

A/D STOP TRIGGER:

ADC Stop Trigger

A/D PACER GATE:

External ADC gate

D/A START TRIGGER:

DAC trigger/gate

D/A UPDATE:

DAC update strobe

D/A TIMEBASE IN:

External DAC pacer timebase

AUXOUT<2:0> sources
(software selectable)

STARTSCAN:

A pulse indicating start of conversion

SSH:

Active signal that terminates at the start of the
last conversion in a scan.

A/D STOP:

Indicates end of scan

A/D CONVERT:

ADC convert pulse

SCANCLK:

Delayed version of ADC convert

CTR1 CLK

CTR1 clock source

D/A UPDATE:

D/A update pulse

CTR2 CLK:

CTR2 clock source

A/D START TRIGGER:

ADC Start Trigger Out

A/D STOP TRIGGER:

ADC Stop Trigger Out

D/A START TRIGGER:

DAC Start Trigger Out

Default selections

AUXIN0:

A/D CONVERT

AUXIN1:

A/D START TRIGGER

AUXIN2:

A/D STOP TRIGGER

AUXIN3:

D/A UPDATE

AUXIN4:

D/A START TRIGGER

AUXIN5:

A/D PACER GATE

AUXOUT0:

D/A UPDATE

AUXOUT1:

A/D CONVERT

AUXOUT2:

SCANCLK

Compatibility

5V/TTL

Edge-sensitive polarity

Rising/falling, software selectable

Level-sensitive polarity

Active high/active low, software selectable

Minimum input pulse width

37.5 ns