3. Installation

3-2

PC002

3.2 Installation


Exhaust gas from the engine is poisonous, and could cause

death when inhaled.
Avoid using the machine in an insufficiently ventilated
building or tunnel.

Do not position the exhaust gas outlet in direction of a person

or a house.


The machine should be operated in following conditions:

Ambient temperature

・・・・・・・

5°F to 104°F( -15℃~+40)

Humidity

・・・・・・・・・・・・・・・・・

Less than 90%

Altitude

・・・・・・・・・・・・・・・・・・

Lower than 1,500 m above sea level

Make sure to install the unit, keeping more space than 5 inches from any solid

object nearby, for prevention of cooling performance drop.

If more than two machines are placed parallel in operation, keep enough distance so that exhaust
air from one machine does not effect the other one.

Also, a machine has to be installed in the environment where fresh air is always available.

Keep enough space around the unit for inspection and maintenance access.

3.2.1 Mounting the unit on the truck bed

Make sure to fix the unit, using

anchor hole“1”of frame as shown
in the fig.
Tightening torque of the bolts:

M12 : 43N・m


A090631

1

Size of anchor bolt holes

A090636-1

Unit:in.