4. Operation

4-12

4.4.2 Operating Procedures when Engine Fails to Start up on First Attempt

When the engine fails to start up even after performing the startup procedures

to

,

do not

keep the starter running, but set the starter switch back to ”STOP” and wait about 30 seconds.
Then, repeat the startup procedure once again.

If the repeated procedure does not allow the engine to run, the following causes are suspected.

Therefore, check the following:

No fuel

Clogging of fuel filter

Discharge of battery (Low cranking speed)

Low ambient temperature



4.4.3 How to start the unit at low temperature

Use SAE10W-30 (CD class) for the engine oil.

Use LLC (antifreeze). Use correct amount to provide freeze protection, according to the ambient
temperature.

Battery should always be kept fully charged.

When it is difficult to start engine in cold weather, take the following measures.

<Procedure>

Fully close the air valve, and fully open the

valve “1” which is provided at the top of
separator for starting under the conditions
of low temperature.


Perform normal starting operation first

and gradually close the low temperature

starting air valve “1”, watching the rising

engine speed.


Operation under Cold Weather Conditions below

23°F(

-5°C)

A100105

Close

Oil

separator

Low temperature

starting valve

Open

1