4. Operation

4-3

4.1.2 Indicator lamp

Turn the starter switch to “RUN” position. Then the lamp goes on.

Item Contents

Measures

Monitor

GLOW

Turn the starter switch “GLOW”

and the lamp goes on and after
preheating is finished, the lamp

will be off.

AUTO IDLE

During operation,push the AUTO

IDLE switch (purge control) “ON”
and then lamp goes on.


When some little trouble occurs during operation, the lamps will flickers.
When the warning lamp flickers, take appropriate measures to recover the situation swiftly.

Item Contents

Measures

Monitor

DISCHARGE
TEMP.

Lamp flickers when the air
temperature at the outlet of the

air-end reaches the set

temperature of 239°F (115°C).

WATER TEMP.

Lamp flickers when coolant

temperature reaches 225°F (107°C).

See
“Troubleshooting”

CHARGE

Lamp flickers when alternator is

not charging.

Check wiring.

Check alternator.

COMP.

AIR FILTER

ENG. AIR FILTER

Lamp flickers when air filter gets

clogged and suction resistance
increases.

[Actuating resistance is more than

0.9psi(0.062bar).]

Clean

Replace


The compressor stops when the emergency stop lamp goes on.

Be sure to follow the measures shown below before starting the unit again.

Item Contents

Measures

Monitor

DISCHARGE

TEMP.

Lamp goes on when the air

temperature at the outlet of the

air-end reaches the set
temperature of 248°F (120℃).

WATER TEMP.

Lamp goes on when coolant
temperature reaches 230°F (110℃).

ENG. OIL PRESS.

Lamp goes on when engine oil
pressure drops.

[The function pressure is below

7.3psi(0.5bar).]

See
“Troubleshooting”

Indicator lamp

Warning lamp

Emergency stop

lamp

Advertising