Operation, 7 capacity control device – MMD Equipment 185S-5C2 part 1 User Manual

Page 33

Advertising
background image

4. Operation

4-15

4.7 Capacity Control Device


Step Response

Start

When starting operation, purge solenoid valve SV1 opens.
And compressed air is sent to unloader chamber A and speed regulator

chamber B . The pressure in chamber A rises soon, and unloader

valve fully closes due to low pressure. Thus the load required for starting
is reduced.The pressure in chamber B rises soon too.and speed regulator

fully stroke to unload position.

Load operation

After starting operation, SV1 valve closes after 10 seconds have passed.
The air volume sent to the chambers A and B from pressure regulator

increases or decreases according to the rise and drop of discharge air

pressure. Thus according as unloader valve position and engine speed

change, free air delivery is steplessly and automatically regulated from

0 to 100%.

Suction port closing

unload operation

When air consumption is reduced, and the pressure exceeds the rated

one, speed regulator functions to lower the engine speed in proportion to

the pressure rise and, at the same time, to close unloader valve.

Under unloaded operation, the interior of compressor air-end becomes

vacuum and vacuum noise is caused. In order to prevent occurrence of

vacuum noise, it functions to open the vacuum relief valve, detecting the

secondary pressure of pressure regulator and thus it prevents high

vacuum state inside the compressor air end from being caused.

A100111E