4.4.4 Gauge Indication while Operating

Minimum discharge air pressure is approx.58psi (4bar) during load operation.

Continuing equipment operation at a lower pressure than the above pressure may cause overheating,
since it affects the separation of lubricating oil inside the oil separator and reduces the oil flow to the
compressor air-end, resulting in temperature rise.

Be sure to check at times to see if gauges or each component of the unit are properly working, or if

there is any air-leak, oil-leak, water-leak or fuel-leak etc.

During normal operation, each indication of instruments is shown in the table below. Refer to the

table for daily checks.

The values mentioned in following table are standard ones, so they sometimes vary

upon operation conditions.

Emergency stop Lamp

Warning Lamp

Protection device

Discharge

temperature

Water

temperature

Engine oil

pressure

Charge

Compressor

air filter

Engine

air filter

Monitor

Starting

Starter switch

set to “RUN”

position

n

OFF

n

OFF

n

OFF

ON

n

OFF

n

OFF

In Operation

n

OFF

Indicator lamp

Protection device

Glow Auto

idle

Monitor

AUTO IDLE

Starting

Starter switch

set to “RUN”

position

n

OFF

n

OFF

In Operation

n

1 OFF

Discharge

air

pressure gauge

Full load

58-100 psi

(4-6.9 bar)

Unload

104-131 psi

(7.2-9.0 bar)

In operati

on

Auto idle

50-65 psi

(3.5-4.5 bar)

Note)※1:The lamp lights on when AUTO IDLE is