Finishing around the fireplace, Caution, Notice – Montigo P42DF User Manual

Page 20: Installation, Warning

Advertising
background image

Figure 21. Combustible mantels and facings.

WARNING!

When covering the upper metal portion of the fireplace, up to 4" (as

shown, Fig.21) with a non-combustible material Please Note: The

decorative facing materials may be subject to temperatures in excess

of 250° F. This should be considered when selecting facing materials.

Finishing Around the Fireplace

Non-combustible mantels and mouldings may be safely installed over

the top and on the front of the fireplace provided that they do not project

beyond shaded area shown in Figure 21.
Fireplace Facing
When sizing the finish material for your fireplace, it is important to

remember the following: THE OPENING MUST NOT BE OBSTRUCTED

IN ANY WAY - to do so restricts the air supply for the control compartments

and heat exchanger it also prevents access for servicing controls.
The face of the fireplace may be painted to match the room decor,

provided you use a heat-resistant paint. Decorative facing must not

extend past the fireplace opening at all, because it will interfere with

the access to retainers for removal of glass door.

Glass doors on gas fireplaces are extremely hot while the fireplace is on and

remain hot even after the fireplace has been turned off. Safety screens are

available and can reduce the risks of severe burns. Please keep children away

from the fireplace at all times.

CAUTION

Do not use ammonia based or abrasive cleaners on the glass, they will permanently

etch the surface. Use an approved gas fireplace glass cleaner such as Kel-Kem or

White off.

NOTICE

We recommend careful consideration be given to the effects of elevated mantel

temperatures which may be in excess of product design, for example: candles, plastic

or pictures. This can cause melting, deformation, discoloration or premature failure of

T.V. radio, and other electronic components.

CAUTION

Mantels & Surrounds
NOTE:
National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the

wise use of energy, has prompted us to manufacture many models of

fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal

room temperature and walls above fireplace may be hot to touch.

Side wall clearances are 3". Combustible surrounds may be installed

with 3" clearance to the side of the fireplace as shown in Figure 22.

Figure 22. Combustible surrounds.

4”Non-Combustible

Facing Material

Non-combustible Header

Drywall/Sheetrock

4”

3”

WARNING

Do not place any materials or objects on top of the

valve blind. Doing so could result in failure of door

relief system or heat dissipation.

Page 20

P42DF* Indoor Gas Fireplace

XG0195 - 150204.2

Installation

Horizontal Run

(

in.

)

Ve

rtical Height (in.)

Combustible construction

allowed in shaded area

Combustible facing material

Combustible header

Non-combustible header

Top of fireplace

Non-combustible facing

Advertising