Clearances, Installation – Montigo P42DF User Manual

Page 8

Advertising
background image

Clearances

When installing a shelf over the top of the fireplaces, the following

guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 0" from the rear

of the fireplace to a wall, or any combustible materials, and 9" clearance

from the top of the fireplace to the underside of any combustible shelf

materials.
For Top Vent applications, the minimum clearance is 0" from the rear

of the unit to a wall, or any combustible materials, and 17 1/2" to the

underside of any combustible shelf materials.
1” clearance is maintained on sides and bottom of vent runs and 2”

above horizontal vent runs to any combustible material.

MODEL

Top - Rear vent

Top - T

op vent

Rear

Sides

Floor

Mantel

P42DF*

9"

17 1/2"

0"

0"

0"

See Section

6 Finishing

around the

fireplace

Installing The Standoffs

To avoid elevated mantel temperatures, all P42DF* gas

fireplaces are required to have the supplied standoffs installed.

The fireplace is supplied with two standoffs. Bend and install these

standoffs on top of the fireplace ensuring that the height of the standoff

maintains a 7 1/2" clearance.

7½”

Figure 6. Installing standoffs

NOTE:
† Clearance from top of fireplace to a ceiling within the fireplace enclosure.

Figure 7c. Securing the Nailing Flange Extension.

The supplied nailing extension must be placed along the top edge of

the fireplace and securely fastened into place, as shown in figure 7c.

Note: The nailing flange extension can be substituted with a piece of

NON-Combustible material of the same size and thermal characteristics,

ie: cement board or equivalent.

4"

Before installing the supplied nailing flange extension, fold tabs at bottom

of nailing flange to a 90 degree angle.

Figure 7. Bottom of Nailing Flange Extension

Figure 7a. Bottom of Nailing Flange Extension with tab folded at 90

degree angle

Figure 7b. Insert folded tabs into slots above the front of the fireplace

Front of Nailing Flange

Front of Fireplace

Installing the Nailing Flange Extension

Page 8

P42DF* Indoor Gas Fireplace

XG0195 - 150204.2

Installation

Advertising