Replacing light bulbs, Troubleshooting, Maintenance – Montigo P42DF User Manual

Page 29

Advertising
background image

Troubleshooting:

SIT Proflame 2:

The following is a troubleshooting chart of possible problems:

If your fireplace still does not operate correctly, consult your local

Montigo dealer.

All service and repairs should be performed by a qualified

Technician.

All spare parts, optional fans, and optional trim finishes are available

from your local Montigo dealer.

Figure 28. Remove the up-lighting glass from the burner tray.

Replacing Light Bulbs

The P42DF* light bulbs can be replaced in a few simple steps. Follow

the directions for removing the door on page 20. Once the door has

successfully been removed, proceed with figures 28 -28b.

Figure 28a. Wear gloves when handling light bulbs. To remove

a light bulb, pull connecting wire away from bulb and pull

light bulb up. Replace with new light bulb.

Figure 28b. Rotate newly replaced bulbs in a full circle. Place

glass cover back in the burner tray.

PROBLEM

SOLUTION

Pilot Igniter won't spark

1. Check the MAIN ON-OFF switch

(typically located below the valve cover)

and turn ON
2. Ensure main power is ON or new

batteries are installed in the remote

control and backup battery pack (if

available).
3. Check the 3.15A fuse in the control

box and replace if necessary

Pilot Igniter sparking, but

Pilot burner will not light

1. Verify the Inlet and Manifold Gas

Pressure are within acceptable limits
2. Check all connections to gas valve
3. Check connection to stepper motor

(if available)

Pilot lights , but Main burner

will not Light

1. Check and verify all wiring connections

as per the wiring diagram.
2 . Verify the inlet and Manifold Pressure

are within acceptable limits

Pilot lights , but Main burner

will not Light and igniter

continues to spark

1. Check the Pilot Flame Sensor Rod

and clean with steel wool or similar.
2 . Check the Pilot hood and clean with

steel wool if dirty.
3. Adjust pilot flame using the pilot

adjustment screw if the pilot flame is

too long or too short (Flame should

fully engulf the sensor rod and must

be stable).
4. Check and make sure the ground

wire from the pilot is connected to the

fireplace body.

Fans not working

1. Ensure main power is ON (fireplace

may be operating on back up batteries).
2. Check the 3.15A fuse in the control

box and replace if necessary

One or more light bulbs are

not working

- Contact the local dealer for repairs

or service