Section 2: framing & clearances, Installation, P42df* indoor gas fireplace – Montigo P42DF User Manual

Page 7

Advertising
background image

Frame in the enclosure for the unit with framing materials. The framed

opening for the assembled fireplace is 42" wide, x 42" high x 21 7/8"

deep, see Figure 2

.

NOTE: When constructing the framed opening, please ensure

there is access to install the gas line when the unit is installed.

See Figure 20.

Figure 2. Framing dimensions, (Straight wall & Corner

Installation).

Note: When sheetrock is not used behind

the fireplace, framing depth 21 7/8" may

be reduced by 5/8".

Figure 5. Non Combustible Framing for Top Vent or Rear

Vent, with alcove.

Figure 4. Combustible Framing for shelves over the fireplace,

Top vent.

Figure 3. Combustible Framing for shelves over the fireplace,

Rear vent.

42”

9”

34 1/2”

Combustible Header

Combustible Shelf

27 1/2”

12”

max.

Non Combustible

Stud 1/2” Above Top

RHS101

Non-Combustible

Materials Only

MIN

96”

12”

door

opening

3”

Rear

Vent

Ceiling

Floor

Alcove

area over

Fireplac e

Top Vent

N.G. & L.P.

12”

max.

Non-combustible

header

Min 1”

21 7/

8”

42 ”

42”

Noncombustible

Stud

35”

84

1/2

0" clearance

to corners

42

59 3/4”

40 1/2”

MEL Short

90° elbow

50 1/2”

17 1/2”

Combustible Header

Combustible Shelf

RHS101

Non Combustible

Stud 1/2” above top

Note: Images are shown without screens for clarity purposes. However,

your fireplace should not be operated without proper installation of

screens.

Non-Combustible

Materials Only

MIN

96”

10.5”

door

opening

3”

Rear

Vent

Ceiling

Floor

Alcove

area over

Fireplac e

Top Vent

N.G. & L.P.

12”

max.

Non-combustible

header

Min 1”

Fireplace without standard screen (pre-January 2015 manufacturing).

Fireplace with standard screen (post January 2015 manufacturing).

Page 7

P42DF* Indoor Gas Fireplace

XG0195 -150204.2