98

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

A Guide to Dolby Metadata

Original Bitstream

This parameter indicates whether the encoded Dolby Digital bitstream is the master 
version or a copy. It has no effect on Dolby Digital decoders and its purpose is purely to 
provide information.

Figure D‐4

 

DC Filter

This parameter determines whether a DC‐blocking 3 Hz highpass filter is applied to the 
main input channels of a Dolby Digital encoder prior to encoding. This parameter is not 
carried to the consumer decoder. It is used to remove DC offsets in the program audio and 
would only be switched off in exceptional circumstances.

Lowpass Filter

This parameter determines whether a lowpass filter is applied to the main input channels 
of a Dolby Digital encoder prior to encoding. This filter removes high‐frequency signals 
that are not encoded. At the suitable data rates, this filter operates above 20 kHz. In all cases 
it prevents aliasing on decoding and is normally switched on. This parameter is not passed 
to the consumer decoder.

LFE Lowpass Filter

This parameter determines whether a 120 Hz eighth‐order lowpass filter is applied to the 
LFE channel input of a Dolby Digital encoder prior to encoding. It is ignored if the LFE 
channel is disabled. This parameter is not sent to the consumer decoder. The filter removes 

Table D-15

Original Bitstream Settings

Original Bitstream

Yes
No

Note:

The parameters DC Filter, Lowpass Filter, LFE Lowpass Filter, Surround 3 dB 
Attenuation, and Surround Phase Shift appear after the Extended BSI parameters on 
Dolby E and Dolby Digital equipment menus.

Table D-16

DC Filter Settings

DC Filter

Enabled
Disabled

Table D-17

Lowpass Filter Settings

Lowpass Filter

Enabled
Disabled

Advertising