Using the DP570 Features

4.3.3

Using External Metadata

When using external metadata, make certain that the values are correct for the program. 
Particularly when you use external program configurations, it is important to ensure that 
the number of programs and the number of channels in each program are correctly set. 
Monitoring with the DP570 should alert you to any problems.

Example 2—Adding a Second Program or Changing a Program

Signal and metadata flow from this example are shown in 

Figure 4‐2

.

We’ll assume you receive a 5.1‐channel program encoded in Dolby E, and you want to 
create a stereo‐compatible mix for it and reencode both onto another Dolby E master. In this 
case the metadata for the second program does not yet exist, but you want to retain the 
metadata from the first program. Furthermore, the program configuration from the 
original stream must be changed because it indicates a single 5.1 program instead of the 
5.1+2 configuration you are creating. 

After you create the stereo mix, you reencode the 5.1‐channel program along with the 
stereo program using a DP571. 

To monitor the reencoded program:

1.

Click the Int radio button to select an internal program configuration source, and 
choose 5.1+2 from the drop‐down list in 

Figure 2‐2

.

2.

Select either external metadata source for Program 1.

3.

Click Program Select button 2

in the software.

4.

Click Int to select an internal program metadata source, and select the parameters for 
the second program metadata.

Figure 4‐2

 

Figure 4‐3

 

Figure 4-2

Adding a Second Program

DP572

DP570

DP571

Digital

Output

Router
Output

Metadata Out

Digital
Input

Metadata
In

Metadata
In

Metadata

Out

Digital
Input

Metadata Adjustment

• Change Program Config

to 5.1+2 (internal source)

• Set parameters for new

two-channel program

D 563

P

In

Out

6

5.1

5.1+2

8

2