Troubleshooting metadata problems, Outputting metadata, Monitoring downmixes – Dolby Laboratories Multichannel Audio Tool DP570 User Manual

Page 43: Figure 4-3, Downmix options, Downmix monitoring, Figure 4‐4, 4 troubleshooting metadata problems, 5 outputting metadata, 6 monitoring downmixes

Advertising
background image

Troubleshooting Metadata Problems

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

27

4.4

Troubleshooting Metadata Problems

The DP570 has several status indicators to help troubleshoot metadata‐related problems.

The front‐panel status display shows the metadata source as External if any metadata 
source is set to external. 

Metadata Input

 indicators on both the DP570 front panel and in the DolbyRemote 570 

software provide status information. The indicators are green any time a valid metadata 
signal is present, whether or not it is being used. They turn red only when an external port 
is in use and there is a problem with the metadata signal.

The Metadata Params submenu under either the Setup or status menu on the 
front‐panel display can also be used to determine the current source for a parameter and 
its current value.

4.5

Outputting Metadata

You can choose to send metadata from the DP570 to downstream devices using the 

Metadata Output

 connector on the rear panel. The frame rate for output metadata is set by 

the received video reference signal and is locked to the beginning of the video frame.

4.6

Monitoring Downmixes

The DP570 allows you to audition various downmixes before finalizing the content. 
Previewing downmix conditions is essential in providing the best possible audio quality in 
listening environments with fewer speakers. Select a downmix mode and make any 
necessary adjustments to the metadata or the source mix accordingly.

You can set up separate sets of speakers for different downmix conditions, sending a stereo 
downmix to the left and right speakers in your 5.1 listening environment, then to a 
different set of stereo speakers just by changing your speaker selection setting. It is a good 
idea to have a low‐grade alternate speaker configuration set up to monitor the stereo and 
mono downmixes to make sure program content plays appropriately in 
“fidelity‐challenged” environments.

To monitor the various downmixes in the DolbyRemote 570 application, click any of the 
buttons shown in 

Figure 4‐3

, then adjust settings on the metadata tabs as necessary.

Figure 4‐4

 

Figure 4-3

Downmix Options

Note:

If the DP570 is using external metadata and there is a temporary error in the 
metadata stream, the unit continues to use the last valid metadata values. When 
the error clears, the DP570 resumes using the stream from the external port.