Using the DP570 with Other Dolby Equipment

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

43

Once a Dialogue Level value has been selected, either short‐term or infinite measurements 
can be used depending on your preference. Again, see 

Section 4.7.2

 to understand the 

differences between them.

5.2.3

Monitoring Downmixes

Once a Dialogue Level value has been set and a measurement mode selected, check 
downmixes and make any adjustments necessary so that the mix translates best across the 
appropriate listening environments.

A full dynamic range 5.1 mix may sound more pleasing than the same mix that is stereo or 
Pro Logic downmixed. In some cases, a compromise on downmixes must be made to 
ensure that the 5.1 mix remains the best.

Use the downmix parameters to help create the best downmix possible from your original 
multichannel mix.

Figure 5‐3

 

Figure 5-3

Downmix Monitoring Controls

Check both compression modes on the full 5.1 mix as well as on downmixes. This is an 
important step because you cannot be certain which mode consumers may be using. See 

Section D.3

 for detailed information on the DRC modes.

5.3

Using the DP570 with Other Dolby Equipment

The Cat. No. 549 GPI/O Controller provides a quick method to change downmix and 
compression modes while monitoring. The DP570 can be used either with the DP569 Dolby 
Digital or DP571 Dolby E Encoders by attaching the metadata connectors, and also with the 
Dolby Media Encoder software application.

Note:

Remember to prioritize your mixes.