Extended Bitstream Information Parameters

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

99

frequencies above 120 Hz that would cause aliasing when decoded. This filter should only 
be switched off if the audio to be encoded is known to have no signal above 120 Hz.

Surround 3 dB Attenuation

The Surround 3 dB Attenuation parameter determines whether the surround channel(s) 
are attenuated 3 dB before encoding. The attenuation actually takes place inside the Dolby 
Digital encoder. It balances the signal levels between theatrical mixing rooms (dubbing 
stages) and consumer mixing rooms (DVD or TV studios). Consumer mixing rooms are 
calibrated so that all five main channels are at the same sound pressure level (SPL). To 
maintain compatibility with older film formats, theatrical mixing rooms calibrate the SPL 
of the surround channels 3 dB lower than the front channels. The consequence is that signal 
levels on tape are 3 dB louder. Therefore, to convert from a theatrical calibration to a 
consumer mix, it is necessary to reduce the surround levels by 3 dB by enabling this 
parameter.

Surround Phase Shift

The default setting is 

Enabled

, which causes the Dolby Digital encoder to apply a 90‐degree 

phase shift to the Surround channels. This allows a Dolby Digital decoder to create an Lt/Rt 
downmix simply. For most material, the phase shift has a minimal impact when the Dolby 
Digital program is decoded to 5.1 channels, but it provides an Lt/Rt output that can be 
decoded with Pro Logic to L, C, R, and S, if desired.

Otherwise, we recommend that you leave this parameter enabled for normal program 
material to avoid problems with the analog outputs of set‐top boxes.

D.7

Extended Bitstream Information Parameters

In response to requests from content producers, Dolby Laboratories modified the 
definitions of several metadata parameters from their original definition as described in 

Table D-18

LFE Lowpass Filter Settings

LFE Lowpass Filter

Enabled
Disabled

Table D-19

Surround 3 dB Attenuation Settings

Surround 3 dB

Attenuation

Enabled
Disabled

Note:

This parameter should always be turned off when you are working with steady 
state tones for testing purposes (for example calibration discs).

Table D-20

Surround Phase Shift Settings

Surround Phase Shift

Enabled
Disabled