Typical tasks, Measuring dialogue level, Monitoring the dialogue level – Dolby Laboratories Multichannel Audio Tool DP570 User Manual

Page 68: Figure 7-2, Dialogue level controls, 2 typical tasks, 1 measuring dialogue level, 2 monitoring the dialogue level

Advertising
background image

52

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

Using the DP570 in Postproduction

7.2

Typical Tasks

The DP570 is used in the monitor chain to emulate the consumerʹs listening environment.

7.2.1

Measuring Dialogue Level

As the mix is nearing completion, use the dialogue level indicators during a representative 
period of speech to determine and select the Dialogue Level Set value for the program. The 
measured value from program material appears in yellow numbers (

–26

 in 

Figure 7‐2

). The 

dialogue level value set in the software appears in green numbers (

–27

 in 

Figure 7‐2

).

Figure 7‐2

 

Figure 7-2

Dialogue Level Controls

If it is necessary to change the value in the software, press the Accept button. The system 
will set the parameter automatically.

In most cases, selecting and measuring a representative period of speech within the 
program will serve as a good example of the overall dialogue level throughout the 
program, provided good mixing practices are observed. In some cases, (documentaries, 
location sound, and so on), it may be difficult to match the dialogue level from section to 
section. In these cases, while the dialogue level indicators on the DP570 can help, your ears 
are the best tool to achieve the best balance.

In most cases, short‐term measurements are best for monitoring during editing as they 
provide a measurement over each 10‐second period of program audio and do not average 
the measurement over a long period of time. For a longer section of program that will be 
played back once, an infinite measurement can be used as it will integrate the measured 
value of the signal until the meter is manually reset, and, over the single pass, will return 
the average level of the program (presumably speech content) for that section. For more 
information on the measurement modes, see 

Section 4.7.2

.

For 5.1 programming, measure the Center channel, as most of the important speech content 
occurs in this channel. For stereo programs, measure both the Left and Right channels.

7.2.2

Monitoring the Dialogue Level

As you work, check the dialogue level indicator—the yellow numbers shown in 

Figure 7‐2

—frequently.

Once a dialogue level value has been selected, either short‐term or infinite measurements 
can be used depending on your preference. See 

Section 4.7.2

 for more information on these 

modes and to understand the differences between them.

Advertising