Measuring and setting the dialogue level, Measuring the average loudness of identified clips, Figure 4-4 – Dolby Laboratories Multichannel Audio Tool DP570 User Manual

Page 44: Measurement control options, Section 4.7, Dialogue level, 7 measuring and setting the dialogue level

Advertising
background image

28

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

Using the DP570 Features

4.7

Measuring and Setting the Dialogue Level

The dialogue level parameter, also known as dialogue normalization or 

dialnorm

, is a vital 

element in audio content creation. The proper dialogue level value ensures that the 
consumer hears different programs at the same level. See 

Section D.2

 for a detailed 

explanation of the dialogue level parameter. The dialogue level for each program must be 
carefully measured and then appropriately set. This is easy using the control in the 
Dialogue Level Set area of the DolbyRemote 570, shown in 

Figure 4‐4

.

Figure 4‐5

 

Figure 4-4

Measurement Control Options

4.7.1

Identifying Normal or Average Level Program Segments

To set the dialogue level parameter, the first and most important step is selecting audio clip 
samples that represent the average loudness level of the program content. Remember that 
the dialogue level parameter establishes the level for normal dialogue in the program; 
quieter and louder scenes tend to show higher or lower measurements than the correct 
value. Using more than one clip is worthwhile particularly in programs that feature 
characters with different vocal qualities. In programs without dialogue, such as a music 
concert, sections of average level need to be identified.

With representative audio clips identified, you can use the DP570 to set the dialogue level 
parameter. You can use either the software interface or the front‐panel buttons; for this 
operation we describe using the software interface first.

4.7.2

Measuring the Average Loudness of Identified Clips

The measurement feature complies fully with ITU‐R Rec. BS.1770 Algorithms to Measure 
Audio Programme Loudness and True‐Peak Audio Level
. Measurement includes the addition of 
two distinct measurement modes relating to the measurement period itself: infinite and 
short‐term. This section describes the behavior of both modes.

IMPORTANT NOTE REGARDING MEASUREMENT ACCURACY:

Measurements are most accurate when they cover signals with similar spectra, such as 
dialogue; the more similar the spectra, the more accurate the measurement. This is why we 
recommend the use of ITU‐R Rec. BS.1770 measurements to provision the dialogue level 

Note:

These changes harmonize both the core measurement algorithm and the 
measurement modes between the DP570, the LM100 Broadcast Loudness Meter, 
and the DP600 Program Optimizer.