Reading the default status display, Viewing status screens, Reading the led indicators – Dolby Laboratories Multichannel Audio Tool DP570 User Manual

Page 30: Figure 3-3, Default status menu screen, Figure 3‐3, 1 reading the default status display, 2 viewing status screens, 3 reading the led indicators

Advertising
background image

14

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

Controlling the DP570

3.4.1

Reading the Default Status Display

The default display when the unit powers up is the top screen of the status menu shown in 

Figure 3‐3

.

Figure 3‐3

 

Figure 3-3

Default Status Menu Screen

The main status display includes five elements:

1.

Program configuration: can contain any of the supported program configurations 
listed in 

Table D‐3

.

The example in 

Figure 3‐3

 includes two programs: A 5.1 mix and a 2‐channel mix. 

Metadata for the programs is controlled separately. 

2.

Metadata source in use. The options are: Internal, Ext 1, or Ext 2.

3.

Program name: Text, which can be user‐entered, describing the program that is 
selected for emulation and metadata authoring. 

Section 4.1

 explains the value of this 

feature.

4.

Channel mode: Displays the current program selection, in this example a 5.1 mix. 
Here 3/2 is the channel mode (three front channels, two rear channels). The L indicates 
that the LFE channel is also enabled. 

5.

Dialogue level: Displays the dialogue level value for the currently selected program. 
In this example, –27 is the selected value for the dialogue level parameter. See 

Section 4.7

 for more information.

3.4.2

Viewing Status Screens

Press the up or down arrow from the main status screen to view the additional screens that 
provide details of the following current states:

Master volume

Current values of individual metadata parameters

Video reference

Audio input

User preset

Errors

Firmware version number

3.4.3

Reading the LED Indicators

The LED indicators at the top of the front panel provide information about the signal input 
and output.

Tip: The metadata parameter and error displays are multiscreen displays. Use the 

Enter

 

and 

Esc

 buttons as described in 

Table 3‐1

 to move around in them.

5.1 + 2 Internal

Prog 1

3/2L 27

1

2

3

4

5

Advertising