A.3.10

Calibrating Emulator Output

If your DP570 does not include the Cat. No. 548 Analog Output Card, calibrate your 
speaker system using the emulator outputs and external equipment. These outputs are 
digital and do not have any internal adjustments.

A.4

Assigning a Dim Setting

The Dim Gain slider sets an alternate level for all speaker outputs. This level is activated 
when you click the Dim button shown in 

Figure A‐10

. This setting enables you to change 

your monitor level in one click (for instance, if a client walks in or you have to take a phone 
call), then return to your master level setting by clicking Dim again. If the Dim Gain setting 
is Off, clicking Dim mutes the speakers.

Figure A‐10

 

Figure A-10 Dim Button

Note:

You can also activate the Dim level via the GPI/O interface but not via the 
front‐panel buttons.