Figure 4-1, Metadata tabs – Dolby Laboratories Multichannel Audio Tool DP570 User Manual

Page 41

Advertising
background image

Generating and Adjusting Metadata

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

25

You can manually modify most of these values on the metadata tabs of the 
DolbyRemote 570 application shown in 

Figure 4‐1

. Dialogue normalization controls are 

shown in 

Figure 4‐4

.

Figure 4‐1

 

Figure 4-1

Metadata Tabs

Example 1—Overriding an Individual Parameter Value

We’ll assume you are using an external metadata stream. The output of the DP570 is 
feeding a DP571 or DP569. You want to add a compression profile because none was 
originally included. To do so:

1.

Select the program you wish to change.

2.

Click the Dynamic Range metadata tab on the DolbyRemote 570.

3.

Click the radio button to change the source of the Line Mode Compression from 
external to internal.

You can now select one of the five compression profiles (for example, Film Light).

Mix Level

85 dB SPL

85 dB SPL

85 dB SPL

85 dB SPL

Room Type

Not Indicated

Not Indicated

Not Indicated

Not Indicated

Preferred Stereo Downmix

Lt/Rt

Lt/Rt

Not Indicated

Not Indicated

Lt/Rt Center Mix Level

–3

–3

N/A

N/A

Lt/Rt Surround Mix Level

–3

–3

N/A

N/A

Lo/Ro Center Mix Level

–3

–3

N/A

N/A

Lo/Ro Surround Mix Level

–3

–3

N/A

N/A

Dolby Surround EX Mode

Not Indicated

N/A

N/A

N/A

Converter Type

Standard

Standard

Standard

Standard

Data Rate

Not Indicated

Not Indicated

Not Indicated

Not Indicated

Table 4-1

Metadata Parameter Defaults (continued)

Metadata Parameter

5.1

Channels

4

channels

2

channels

1

channel

Advertising