Substitute leakage test, Flash test, Insulation test – Seaward Supernova Elite User Manual

Page 94

Advertising
background image

Insulation Test

84

Insulation Test

Test Voltage * ............... 500V d.c. or 250V d.c. nominal (0.5M

Ω load)

Short Circuit Current............................................. 2mA d.c. maximum

Range.......................................................................... 100k

Ω - 100 MΩ

Resolution.......................................................…..0.01 M

Ω (<100 MΩ)

Accuracy..................... +/- 5% of reading, +/- 2 digits (100k

Ω - 20MΩ)

Pass Levels ……...…0.5M

Ω, 1MΩ, 2MΩ, 4MΩ, 7MΩ, 10MΩ, 50MΩ

Substitute Leakage Test

Test Voltage * .....................................................................40V a.c. o/c

Display Range .......................................................... 0.1 - 20.0 mA a.c.

Resolution.........................................................................…....0.01mA

Accuracy..........................+/- 10% of reading, +/- 2 digits 1.00 - 20mA

Pass Levels …………………0.25mA, 0.5mA, 0.75mA, 2.5mA, 3.5mA

7.0mA, 9.9mA, 15.0mA

Flash Test

Test Voltage ....................….1.5kV a.c. (Class I), 3.0kV a.c. (Class II)

Display Range ............................................................ 0.1 - 2.5 mA a.c.

Resolution..........................................................................….0.01mA

Accuracy................................................ +/- 5% of reading, +/- 2 digits

Pass Levels.........................................1.0mA, 1.5mA, 2.0mA, 2.25mA

Insulation Test

Advertising
This manual is related to the following products: