Mechanical, Environmental, Rcd test – Seaward Supernova Elite User Manual

Page 96

Advertising
background image

RCD Test

86

RCD Test

Test Current *…........……………………………………………..30mA

Range………….…......……………………………..…………..0-500ms

Resolution…….........…………………………………………….....1ms

Accuracy…........……………………………………………..…..+/-3ms

Pass Levels...............................……………………....200ms, 300ms

Mechanical

Size............................................................. 450mm x 410mm x 155mm

Weight........................................................................................... 3.5kg

Environmental

Operating ............................................... 0ºC to 40ºC (non condensing)

Storage ................................................-10ºC to 50ºC (non condensing)

Maximum R.H ..................................................................................90%

Supply Rating ............................................. 110V/230V +/- 6% 50/60Hz

Max Output Current ..........................................................................16A

Fuses (Internal).............................................…….not user replaceable