Teletronics WINC900A User Manual

Page 25

Advertising
background image

25

Result codes:

OK

Valid parameter.

ERROR

Invalid value for selected register.

V - Verbal Result Codes
The ATV command determines whether the device sends a numeric digit (terse mode) or an
informative text string (verbose mode).
Format:

ATV0

Use numeric result codes.

ATV1

Use text string result codes.

Result codes:

OK

Valid argument.

ERROR

Invalid argument.

Below is a listing of numeric and text string result codes:

Numeric Code

Text String Response

0

OK

1

CONNECT

2

RING

3

NO CARRIER

4

ERROR

6

NO DIAL TONE

7

BUSY

8

NO ANSWER

X - Extended Result Codes
The ATX command determines whether the device enables extended result codes. All extended result
codes are enabled in the default settings.
Format:

ATX0

Enable only codes 0...4. Extended results are mapped as
appropriate to 0...4.

ATX2

Enable all extended result codes (default).

Z - Soft Reset
The ATZ command resets all parameters to the saved profile, aborting any active connection. If no
profile was saved, the device is reset to the default condition.
Format:

ATZ

Perform soft reset.

Result code:

OK

Command complete.

&C - Set DCD Operation