APPENDIX B - S Register Summary

Register

Function

Range

Units

Default

S0

Rings to Auto-Answer

0-1

rings

1

S2

Escape Character

0-255

ASCII

43<+>

S3

Carriage Return Character

0-127

ASCII

13<CR>

S4

Line Feed Character

0-127

ASCII

10<LF>

S5

Backspace Character

0-127

ASCII

8<BS>

S7

Wait Time for Carrier

0-255

second

60

S10

Carrier Loss Disconnect Time

0-255

second

50

S12

Escape Prompt Delay

0-255

0.02sec

50

S14

Command Status Bitmap (read only)

S21

Equipment Status Bitmap (read only)

S22

Equipment Status Bitmap (read only)

S23

Equipment Status Bitmap (read only)

S50

Data forwarding idle time-out

0-255

0.1sec

2

S51

Primary Data forwarding character

0-255

ASCII

13<CR>

S52

Secondary Data forwarding character

0-255

ASCII

26<ctl-Z>

S53

Remote Party Address

Char.String

0303030

S60

Idle Mode

0-1

0

S61

Idle Guard Time

1-5

0.1sec

5

S62

PLC Break Control Signal Length

0-255

10msec

30

S63

Enable the detection function or Listening
time

0-10

0.01sec

3

S-REGISTER DEFINITIONS :

The behaviors of WINC 900A can be adjusted via the AT commands and the content of register
to meet application’s requirement.

S0 Rings to Auto-Answer

Whether this unit will be able to answer the request for connection from the
remote caller automatically or manually is decided by the content of the
register 0.

S2 Escape Character

The value in register 2 maps to an ASCII code, a designated Escape
Character on the keyboard, which allows user to switch the operation mode
of the communication software back to command mode from connection
mode by holding the “Shift” key and press this key three (3) times.

S3 Carriage Return Character

S4 Line Feed Character

S5 Backspace Character

S7 Wait Time for Carrier