3 shutdown, 4 setting the process air temperature, 5 setting the high and low temperature alarms – AEC WD 350 through WD3000 Dehumidifying Dryers User Manual

Page 29

Advertising
background image

350-2100 cfm Dryers

Chapter 5: Startup, Shutdown & Operation

28 of 58

6. If the dryer has an aftercooler, make sure there is proper flow of cooling water flow through the

coil, and any trapped air has been bled from the system.

7. Make sure the damper on the hopper air inlet tube is about 50% open.
8. Remove the lower end of the 2½" flex hose from the tube stub on the lower drying hopper.

Carefully adjust the damper valve on the return line back to the filter to achieve approximately
200 cfm air flow out of the flex hose.

9. Set the process setpoint on the temperature controller.
10. After the proper pre-drying time for the initial hopper fill has elapsed, fully open the drying

hopper slidegate.

To allow proper residence time during continuous processing, the material level in the hopper should be
maintained at the midpoint of the air trap assembly.

5-3 Shutdown

Turn off the conveying system supplying the drying hopper.

When processing is complete, close the hopper slide gate and shut down any in-line
companion equipment, i.e. an aftercooler.

Push the Start/Stop button. After both blowers have shut down and regeneration is
complete, turn the On/Off selector switch "OFF".

Empty the drying hopper, if desired.

For maintenance or long-term shut down, open (de-energize) the electrical disconnects at
the dryer and in the power drop.

5-4 Setting the Process Air Temperature

To Change Process Air Temperature Set Point:

Press

to raise the Setpoint.

Press

to lower the Setpoint.

5-5 Setting the High and Low Temperature Alarms

To Change the Process Air High Temperature Alarm Setting:

1. Press

for at least two seconds to access the level 1 parameters.

2. When the PV LED display shows

, use

and

to set the desired high

temperature alarm value.

The high temperature alarm value is a deviation of the process air temperature set point. The alarm
value will track the set temperature. If the high temperature alarm is set to "25", a high temperature
alarm occurs if the process air temperature rises more than 25°F above the process air temperature
setpoint.

3. Press

until the PV LED shows

. Use

and

to set the desired low

temperature alarm value.