47 of 58

Figure 9: Regeneration Monitor Signal Processor Error Messages

Item

Condition

Error

Output Status

Corrective

Message

Compara-

tive

Outputs

BCD

Output

Linear

Output

Commun-

ications

Action






Device
Failure

CPU RAM
error,
external
memory
error,
memory
data error.




OFF



OFF



OFF



OFF


Turn the power OFF
and then ON again
once. If the error
persists, call Service.



Corrupted
Data




OFF



OFF



OFF



OFF

Turn the power OFF
and then ON again
once. If the error
persists, press the
mode key and set all
parameters again.





Sensor
Error

Breakage or
short circuit of
sensor. When
the
thermocouple
is used,
terminals 11
and 13 are
not short
circuited.








OFF





OFF





OFF






OFF





Check sensors for
breakage, short
circuiting, or incorrect
wiring.


Overflow,
Underflow

Input value
or display
value
outside
range.


Display
Blinks


Continues

Continues

OVER

ON


Continues

Continues

OVER ON


Keep the input value
and display value
within the range.



Output
Type
Change


When
output type
has
changed.




OFF



OFF



OFF



OFF

Check the output type.
If correct, press the
mode key. This erases
the set the parameters,
so re-enter them. If the
problem persists, call
Service.

Output
Type Error


Output type
other than
specified.


OFF


OFF


OFF


OFF

Turn the power OFF
and then ON again
once. If the error
persists, call Service.

Input
Specifi-
cation
Error

Input type
other than
specified.


OFF


OFF


OFF


OFF

Turn the power OFF
and then ON again
once. If the error
persists, call Service.