350-2100 cfm Dryers

Chapter 6: Maintenance

43 of 58

Display

Characters

Sensor Type

Switch

Position

Temp

Range

°C

°F

Thermocouple Type R

0

0 - 1,700

0 - 3,000

Thermocouple Type S

1

0 - 1,700

0 - 3,000

Thermocouple Type K

2

-200 to

1,300

-300 to

2,300

Thermocouple Type J

3

-100 to

900

-100 to

1,600

Thermocouple Type T

4

-200 to

400

-300 to

700

Thermocouple Type E

5

0 to 600

0 to 1,100

Platinum RTD (JIS

1981)

6 -99.9

to

450.0

-99.9 to

800.0

Platinum RTD (DIN)

7

-99.9 to

450.0

-99.9 to

800.0

Not Used

8

Not Used

9

9. Set both transmission output selector DIP switches OFF. They are marked SW207 (TRANSFER)
and are on the right circuit board on controls equipped with optional communications. See the
Communications Manual [part number A0535959].

1

2

3

4

5

6

ON

10. The function selector DIP switch [SW201 (FUNCTION)] selects 6 control modes. It is on the right
circuit board. Put this switch in the set-up configuration at right while inputting the initial control
parameters.

SW201 Set-up Configuration

1 OFF

Control Mode

2 OFF

Normal/Reverse Output

3 OFF

Input Shift

4 OFF

Temperature Sensor
Standard

5 ON

Scale Indication

6 ON

PID Constant Indication

Advertising