PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

Little or no air coming from
process delivery tube.

A. Dirty Filters

A.

Clean or replace

filters.

B.

Desiccant beds

contaminated by material
or plasticizer leaking into
the system. See Sec. 6-6.

B. Replace

desiccant

C. Blower fuse(s) blown. C. Fix problem and

Replace fuse(s).

D.

Overload

tripped.


D. Fix problem and reset

the overload.

E. Blower fins filled with

dust or contaminants.

E. Remove blower

sideplate, clean
baffles, replace.

Suction in delivery tube,
pressure from the return
tube.

A. Phase is reversed on

power drop coming
into the dryer.

A.

Stop the Dryer.

If the dryer was connected
to the drying hopper, check
to see if the desiccant and
process air heater has
been contaminated with
resin. If so, replace the
desiccant and remove any
resin carry-over. Otherwise,
change the phase of two
legs of the three-phase
power drop. Never change
the phase at the motor
starters unless only one of
the two blowers is rotating
improperly.