120

$PAMTC,COMP,X

Summary

Terminate the user compass calibration mode.

Syntax

$PAMTC,COMP,X*hh<CR><LF>


Reply

$PAMTR,COMP,X,
<1>,<2>,<3>,<4>,<5>,<6>,<7>,<8>,<9>*hh<CR><LF>

Notes

Upon receiving $PAMTC,COMP,X user calibration mode will be terminated, if it

had been previously entered by a $PAMTC,COMP,GO. The reply will always be

issued.

If not in user calibration mode, the “X” will be replaced by “Q”.