PB200 WeatherStation User Manual revision 1.000

Proprietary and Confidential

58

NMEA 2000® TRANSMITTED PARAMETER GROUP

PGN

130881

(0x1FF41)

Proprietary: Heater Control

Single Frame: No

Priority: 7/Y/Y

Update Rate: 0/Y/Y

Destination: Global

Query Support: Yes

Access Level: 0

Field

#

Name

Request

Param. DD

DF

Type Resolution

Value

Remark

1 Manufacturer Code

Yes

DD172 DF52 11 bits

1

135 (decimal)

Manufacturer Code for Airmar Technology.

2 Reserved bits

No

DD001 DF52 2 bits

1

0x3

All bits set to logic "1"

3 Industry Group

Yes

DD168 DF52 3 bits

1

4 (decimal)

Industry Group for "Marine Industry".

4 PG Transmit Option

No

N/A DF52 2 bits

1

MSB/LSB:

00 = Do not transmit on

status change

01 = Transmit on status

change

10 = Error

11 = Data not available

This field defines whether this PGN is

transmitted automatically when there is a

change in the heater status (field 6) while the

heater mode (field 5) is in Automatic.
This field is stored in EEPROM and may be

changed with the Command Group Function

PGN 126208. The default value is 00 (do not

transmit on status change).

5 Heater Mode

No

N/A DF52 2 bits

1

MSB/LSB:

00 = Manual, Turn Off

01 = Manual, Turn On

10 = Automatic

11 = No action

This field is stored in EEPROM and may be

changed with the Command Group Function

PGN 126208. If the Heater Mode is 01 upon

power up, the heater will not be turned On, i.e.

the unit will behave as though the Heater Mode

is 00. If the Heater Mode is 10 (Automatic)

upon power up, the heater will cycle on and off

automatically over time as required to maintain

the proper plate temperature.
The default value is 00 (Manual, Turn Off).

6 Heater Status

No

DD002 DF52 2 bits

1

MSB/LSB:

00 = Off

01 = On

10 = Error

11 = Data not available

This field indicates the actual state of the heater.

The power up default value is 00 (Off). The

PB200 will return DataNotAvailable unless the

Heater Control option is enabled at the factory.

7 Reserved bits

No

DD001 DF52 2 bits

1

0x3

All bits set to logic "1"

8 Plate Temperature

No

DD043 DF39 uint16 0.01 deg K 0 to 655.32 deg K

Temperature of the aluminum plate at the base

of the PB200 wind channel.

Advertising