To specify a certain transmitting device to be used to supply PGN 128259, set the Rule field (field 6) to a value of 3 or 4, and specify the CAN name of the transmitting device

using the Command Group Function PGN 126208, specifying the individual fields in PGN 126720-47 as follows.

PGN 126720

Field Value

1

135 (decimal)

3

4 (decimal)

4

47 (decimal)

5

128259

6

3 or 4, as desired

8

The CAN name of the device

transmitting the PGN of interest.



This PGN is transmitted in response to a PGN 126208 Request Group Function message. Fields 1, 3, and 4 must each be fully specified in the request in order for this PGN to be

transmitted. If field 5 (received PGN number) is also supplied, PGN 126720-47 will be transmitted once only, for the given received PGN. If field 5 is omitted, then this PGN will

be transmitted once for each received PGN supported by the PB200.
This PGN does not respond to ISO Requests (PGN 59904).