0x1ef00), Proprietary: nmea 2000® options – Airmar PB200 User Manual

Page 34

Advertising
background image

PB200 WeatherStation User Manual revision 1.000

Proprietary and Confidential

28

NMEA 2000® TRANSMITTED PARAMETER GROUP

PGN

126720-46

(0x1EF00)

Proprietary: NMEA 2000® Options

Single Frame: No

Priority: 7/Y/N

Update Rate: 0/N/N

Destination: Address

Query Support: Yes

Access Level: 0

Field

#

Name

Request

Param. DD

DF

Type Resolution

Value

Remark

1 Manufacturer Code

Yes

DD172 DF52 11 bits

1

135 (decimal)

Manufacturer Code for Airmar Technology.

2 Reserved bits

No

DD001 DF52 2 bits

1

0x3

All bits set to logic "1"

3 Industry Group

Yes

DD168 DF52 3 bits

1

4 (decimal)

Industry Group for "Marine Industry".

4 Proprietary ID (PID)

Yes

DD005 DF53 uint8

1 bit

46 (decimal)

46 = NMEA 2000® Options

5 Transmission Interval Supersedes Measurement

Interval

No

DD003 DF52 2 bits

1

MSB/LSB:

00 = Feature Disabled

01 = Feature Enabled

10 = Reserved

11 = No action/Data Not

Available

See the text below for a description of this

feature.
This field may be changed with the Command

Group Function PGN 126208. It is saved in

EEPROM. The default value is 00 (Feature

Disabled).

6 Reserved bits

No

DD001 DF52 22 bits

1

0x3FFFFF

All bits set to logic "1"

Notes
The various types of data provided by the PB200 are sampled, or measured, at different rates, depending on the nature of the data being measured. For example, the GPS receiver

in the PB200 provides new position fix data once per second, while the wind sensor provides new data twice per second. The rate at which a given source of data is measured is

unrelated to the rate at which its corresponding PGN is transmitted. It is possible, using the Request Group Function PGN 126208, to specify a PGN transmission interval that is

faster than the corresponding measurement interval for data within the PGN.
Field 5 of this PGN allows the user to specify the behavior of the unit when PGNs are requested to be transmitted faster than the measurement intervals for data within the PGNs.

If the feature is disabled (the default case), then the measurement interval supersedes the requested transmission interval. If the feature is enabled, then the requested transmission

interval supersedes the measurement interval.
Some examples are shown below:

Advertising