27


To change the state of the Simulate Mode option (field 5), use the Command Group Function PGN 126208, specifying the individual fields in PGN 126720-35 as follows.

PGN 126720

Field Value

1

135 (decimal)

3

4 (decimal)

4

35 (decimal)

5

One of the following:

MSB/LSB:

00 = Turn Simulate Mode Off

01 = Turn Simulate Mode On

This PGN performs the same function as the received proprietary NMEA 0183 command $PAMTC,SIM.